Investigation · Identity
Was the user spammed with MFA prompts until they approved?
Detect MFA fatigue in Entra ID and Okta: the burst of denied or ignored push prompts, the approval that ended it, and what the attacker did once inside.
When you would ask thisA user reports a string of unexpected MFA prompts, or the logs show repeated MFA failures for one account. You need to know whether someone with the password pushed prompts until the user approved one, and what happened after the approval.
Steps
- 1
Find the burst of MFA failures in Entra
MFA fatigue needs a working password, so the pattern starts with 50074 (password correct, strong authentication required) and continues with repeated 500121 (strong authentication failed) as the user denies or ignores the prompts. Group by user and short time windows to find accounts with several 500121 results in quick succession, usually from one IP or ASN that is not the user's. Tune the threshold and window to your environment rather than treating any fixed count as definitive. A success (ResultType 0) from the same source after the burst is the likely moment of compromise.
Users with bursts of failed MFA (Sentinel KQL)SigninLogs | where TimeGenerated > ago(7d) | extend Result = tostring(ResultType) | where Result in ("50074", "500121", "0") | summarize MfaFailed = countif(Result == "500121"), MfaRequired = countif(Result == "50074"), Succeeded = countif(Result == "0"), FirstFailure = minif(TimeGenerated, Result == "500121"), LastSuccess = maxif(TimeGenerated, Result == "0"), IPs = make_set(IPAddress, 20) by UserPrincipalName, Window = bin(TimeGenerated, 1h) // Tune the threshold and window to your tenant. | where MfaFailed >= 3 | order by MfaFailed desc - 2
Read why each prompt failed
500121 covers more than a denied push: it also appears when a prompt times out, when the user picks the wrong number under number matching, and when the user reports the prompt as suspicious. The reason sits in the sign-in's Status additional details and in AuthenticationDetails, with text along the lines of the user declining the authentication or not responding; exact strings vary, so inspect a sample from your tenant rather than matching a fixed phrase. Note whether the user used Report suspicious activity (or the older fraud alert). Where that feature is enabled, Entra ID Protection records it as a user-reported suspicious activity risk detection (userReportedSuspiciousActivity), which is good evidence the user did not start the sign-in; confirm the detection name in your tenant.
Per-user timeline with the failure detail (Sentinel KQL)SigninLogs | where TimeGenerated between (datetime(2026-10-20T08:00:00Z) .. datetime(2026-10-20T12:00:00Z)) | where UserPrincipalName =~ "[email protected]" | project TimeGenerated, ResultType, ResultDescription, IPAddress, AutonomousSystemNumber, UserAgent, AppDisplayName, AuthenticationRequirement, FailureDetail = tostring(parse_json(tostring(Status)).additionalDetails), AuthenticationDetails, SessionId | order by TimeGenerated asc - 3
Find the approving sign-in and follow its session
Identify the first successful sign-in after the burst whose IPAddress, ASN and UserAgent match the failed attempts rather than the user's own device. Check AuthenticationRequirement (multiFactorAuthentication) and the method in AuthenticationDetails to confirm a push approval satisfied MFA. Record its SessionId and UniqueTokenIdentifier, then follow that session through SigninLogs and AADNonInteractiveUserSignInLogs to see which apps and resources the attacker reached. Watch for interleaving: the real user may be signing in normally during the burst, so attribute each success by source, not by time alone.
- 4
Pull the Okta push events (if Okta)
In the Okta System Log, system.push.send_factor_verify_push records an Okta Verify push sent to the user, user.mfa.okta_verify.deny_push records the user rejecting one, and user.authentication.auth_via_mfa records factor verification, with outcome.result showing success or failure. Many pushes and denials in a short window, followed by a successful auth_via_mfa and a user.session.start from the same client IP as the pushes, is the fatigue pattern. Okta also lets end users report an unrecognized prompt as suspicious, which produces its own eventType; confirm its exact name in the event types catalog. Some MFA eventTypes differ between Okta Classic Engine and Identity Engine orgs, so check the catalog before trusting an empty result.
Okta System Log API: pushes, denials and the session that followedGET /api/v1/logs?since=2026-10-20T00:00:00Z&filter= (eventType eq "system.push.send_factor_verify_push" or eventType eq "user.mfa.okta_verify.deny_push" or eventType eq "user.authentication.auth_via_mfa" or eventType eq "user.session.start") and actor.alternateId eq "[email protected]" # URL-encode the filter. If an event lists the user as target rather than actor, # drop the actor clause and filter the response on target.alternateId instead. # Compare client.ipAddress and securityContext.asNumber across pushes and the success. - 5
Talk to the user and check for a phone call
Ask the user directly whether they approved a prompt, when, and why. With number matching (enforced for Microsoft Authenticator push notifications since May 2023) or Okta Verify number challenge, the user must enter a number shown on the sign-in screen, so a blind tap no longer works and attackers turn to calling the user, posing as IT, and asking for the number. A call or chat message shortly before the approval moves the case toward voice phishing, and the call record becomes evidence. If the user approved because they believed it was their own sign-in, record that too; it shapes the awareness follow-up but not the containment.
- 6
Contain and close the gap
Reset the password, because the 50074 records show the attacker knows it, then revoke the user's sessions (Revoke-MgUserSignInSession in Entra, clearing user sessions in Okta) and remove any MFA method or device the attacker registered after the approval. Review the post-approval session for the usual follow-on actions: mailbox rules and forwarding, new MFA methods, app consent and access to sensitive files. To reduce repeats, confirm number matching and additional context (app name and location in the prompt) are on for push, consider phishing-resistant methods for high-value accounts, and alert on repeated 500121 or deny_push for a single user.
Where it goes wrong
- A burst of 500121 with every prompt denied still means the password is known (the 50074 records prove it); reset it even if no prompt was approved.
- 500121 also covers timeouts, wrong-number selections and lost phones; read the failure detail before calling it fatigue.
- Number matching blocks blind approvals but not a user who is talked into reading out the number on a phone call; fatigue then becomes voice phishing, and the evidence moves to call records.
- Okta MFA eventTypes vary between Classic Engine and Identity Engine orgs; confirm the names in the event types catalog rather than assuming an empty result means no pushes.
- The real user's own sign-ins can interleave with the attack, so attribute the approving success by IP, ASN and user agent, not by which success came first after the burst.
- Users often do not report prompts they denied; the absence of a fraud or suspicious activity report is not evidence that no attack happened.
Beyond event logs
User interview and call records
The user, plus phone system or Teams call records for inbound calls around the approval time
Establishes whether the approval was a mistaken tap, a response to a caller posing as IT, or the user's own sign-in, which decides whether this is fatigue, voice phishing or a false positive.
Authentication methods and risk state
Entra: the user's Authentication methods and the Risky users and Risk detections reports; Okta: the user's enrolled factors
Shows factors registered after the approval and any user-reported suspicious activity, both of which must be handled during containment.
Keep going
- InvestigationIs this a brute-force or password-spray attack, and did any attempt succeed?
- InvestigationWas this account taken over through the help desk?
- InvestigationWas this session cookie stolen by an adversary-in-the-middle phishing kit?
- InvestigationDid an attacker take admin control of our Okta tenant?
- Attack signalsPassword Spraying
- Field valueAADSTS500121: Strong authentication failed
- Field valueAADSTS50074: Strong authentication required
- Field valuePush denied by user
- Field valuePush sent