Event ID 4818: Proposed Central Access Policy does not grant the same permissions

Proposed Central Access Policy does not grant the same access permissions as the current Central Access Policy.

Channel
Security
Logged by default
No
Written on
Any host
Volume
Low
Audit subcategory
Central Policy Staging
Needs a SACL
No

To have this event

  • Enable Central Policy Staging: auditpol /set /subcategory:"Central Policy Staging" /success:enable /failure:enable

Pull this event

Retrieval queries for a live host, a collected .evtx file and common SIEMs. Filter further on the key fields above.

Get-WinEvent -LogName 'Security' -FilterXPath "*[System[(EventID=4818)]]" -MaxEvents 50 |
  Select-Object TimeCreated, Id, MachineName, Message

-FilterXPath supports exact matches only. For substring matching, filter in Where-Object.

Common questions

What does Windows event ID 4818 mean?
Proposed Central Access Policy does not grant the same access permissions as the current Central Access Policy. It is written to the Windows Security log (Security).
Is event 4818 logged by default?
No. It must be enabled before it is recorded. It is controlled by the "Central Policy Staging" Advanced Audit Policy subcategory (Object Access).

Proposed Central Access Policy does not grant the same access permissions as the current Central Access Policy. Needs the "Central Policy Staging" audit subcategory. Key fields, logging requirements, ATT&CK mapping and ready-to-run queries.